To run the command:
- Connect to the Sensor command line interface using a Secure Shell (PuTTy) and log on to the Sensor.
- From the prompt, type the following and press Enter:
show intfport <port id>
The command displays the following port statistics:
Administrative Status : ENABLED
Operational Status : UP
Operating Mode : INLINE_FAIL_OPEN
Duplex : HALF
Port Connected to : OUTSIDE
10/100 Port Speed : 100 MBPS
Gigabit Port Speed : NOT APPLICABLE
Total Packets Received : 557
Total Packets Sent : 731
Total CRC Errors Rcvd : 0
Total Other Errors Rcvd : 0
Total CRC Errors Sent : 0
Total Other Errors Sent : 0
Flow Control Status : NOT APPLICABLE
NOTE: The
Other error counters are typically associated with the half-duplex mode of port operation. They are normally incremented by a highly used half-duplex link and are classified as follows:
- Total Other Errors Rcvd: align errs, runts, length errs, false CRS, PHY errs, FIFO errs, ignored, bad opcode
- Total Other Errors Sent: defers, XSDefers, single collisions, multi-collisions, XSCols, Late Cols, FIFO errors